AFL Motors

Double-inlet centrifugal blower F3P146-EC092-057

F3P146-EC092-057 is an AFL double-inlet centrifugal blower in the published model records. Review its documented specifications, installation requirements and source information against your equipment duty.

F3P146-EC092-057 product photo · AFL catalogue, page 219.
F3P146-EC092-057 product photo · AFL catalogue, page 219.

Review the documented model data

Supply: 230 VAC. Frequency: 50/60 Hz. Power input: 165 W. Speed: 1700 rpm. Control input: 0-10 VDC / PWM. The AFL catalogue lists 230 VAC, 50/60 Hz, 165 W for this double-inlet centrifugal blower. Check the 0-10 VDC / PWM control interface against your controller. The catalogue enclosure rating is IP44.

Check the installation and operating point

Check clearance at both intake openings, the outlet orientation and the fixing positions against the model drawing. Include the cabinet, filter and duct losses in the required duty point.

Match the electrical interface

Confirm the supply and the exact speed-control and feedback interface required by the equipment controller. An EC designation alone does not establish the supported control signal.

Use the technical documents

Check the attached model documents and their page references before sample evaluation. Confirm the complete suffix and document revision. Performance at your required duty point must be checked on the corresponding curve.

Discuss this model

Include F3P146-EC092-057, required airflow and static pressure, power supply and available installation space in your inquiry. Attach the equipment layout and identify any required control or feedback signals.

EC fans and blowers · Double-inlet blowers

All F3P146-EC092 variants

Specifications

Model
F3P146-EC092-057
Drive
EC
Supply
230 VAC
Frequency
50/60 Hz
Current draw
1.1 A
Power input
165 W
Speed
1700 rpm
Control input
0-10 VDC / PWM
Sound pressure level
65 dB
Degree of protection
IP44
Working temperature
-25 ~ +60 °C
Insulation class
B
Impeller material
PA66

Manufacturer catalogue pages

Check the drawing and rated conditions for the complete model.

Catalogue page 219
View original drawing or performance sheet · page 219F3P146-EC092-057 manufacturer sheet, page 219

Open original PDF at this page

AFL product catalogue · page 219
Catalogue fieldValue on this page
Supply230 VAC
Frequency50/60 Hz
Current draw1.1 A
Power input165 W
Speed1700 rpm
Control input0-10 VDC / PWM
Sound pressure level65 dB
Degree of protectionIP44
Working temperature-25 ~ +60 °C
Insulation classB
Impeller materialPA66
Compare this modelCheck evidenceAsk engineering about this model

Equipment fit and selection

Check both inlet clearances and the discharge orientation in the cabinet drawing. Provide the working point with the filter and duct losses included.

Equipment selection guide What to check before ordering Factory and qualification documents

Related models to review

Compare the complete suffix, mounting and operating conditions before specifying a replacement.

F3P146-EC092-035 product photo · AFL catalogue, page 218.F3P146-EC092-035 product photo · AFL catalogue, page 218.F3P146-EC092-035F3P146-EC092-035: review double-inlet centrifugal blower specifications, mounting requirements and technical sources before selecting a fan for your equipment.F3P146-EC092-055 product photo · AFL catalogue, page 217.F3P146-EC092-055 product photo · AFL catalogue, page 217.F3P146-EC092-055F3P146-EC092-055: review double-inlet centrifugal blower specifications, mounting requirements and technical sources before selecting a fan for your equipment.F3P146-EC092-608 product photo · AFL catalogue, page 220.F3P146-EC092-608 product photo · AFL catalogue, page 220.F3P146-EC092-608F3P146-EC092-608: review double-inlet centrifugal blower specifications, mounting requirements and technical sources before selecting a fan for your equipment.

Request specifications

Your inquiry will be saved for the AFL team. For direct contact, use the sales details on the Contact page.