Operating point
State airflow and static pressure together, with units and the installed resistance from filters, coils or grilles. Compare the required point with the selected model curve.
Compare construction, complete models, installation conditions and technical sources.
AFL product family illustration · axial fan. Individual mounting and accessories vary by suffix.EC axial fansEC axial fans for heat-pump equipment. Compare model curves, mounting drawings and control interfaces against your coil and airflow requirements.
AFL product family illustration · axial fan. Individual mounting and accessories vary by suffix.AC axial fansAC axial fans for condenser and equipment airflow. Compare coil resistance, air direction, mounting and supply frequency against the selected model.
AFL product family illustration · axial fan. Individual mounting and accessories vary by suffix.DC axial fansDC axial fans for equipment cooling. Review the DC supply, enclosure air path, control requirements and mounting dimensions before model selection.State airflow and static pressure together, with units and the installed resistance from filters, coils or grilles. Compare the required point with the selected model curve.
Check supply, frequency, speed control and feedback against the complete designation. Keep 50 Hz and 60 Hz ratings separate when both are listed.
Compare housing, mounting positions, inlet clearance, outlet direction and service access against the current drawing.
The values below come from published model records. Open a model for its drawing, curve, available documents and specific conditions.
| Product | Electrical data | Listed performance and conditions | Technical source |
|---|---|---|---|
| A3P200-EC072-001 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P200-EC072-002 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P200-EC072-003 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P200-EC072-004 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.6 A | Air direction suction Power input 80 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P200-EC072-005 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.6 A | Air direction blowing Power input 80 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P200-EC072-100 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P200-EC092-001 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P200-EC092-002 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P200-EC092-003 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P200-EC092-004 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.7 A | Air direction suction Power input 85 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P200-EC092-005 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.7 A | Air direction blowing Power input 85 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P200-EC092-100 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P250-EC092-001 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P250-EC092-002 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P250-EC092-003 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P250-EC092-004 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.1 A | Air direction suction Power input 170 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P250-EC092-005 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.1 A | Air direction blowing Power input 170 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P250-EC092-040 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P250-EC092-041 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P250-EC092-042 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P250-EC092-043 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P250-EC092-044 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.4 A | Air direction suction Power input 200 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P250-EC092-045 | Drive EC Supply 230 VAC Frequency 50/60 Hz Current draw 1.4 A Control input 0-10 VDC / PWM | Air direction blowing Power input 200 W Speed 3150 rpm Sound pressure level 69 dB | Model specifications Source documents |
| A3P250-EC092-100 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P300-EC072-001 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P300-EC072-002 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P300-EC072-003 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P300-EC072-004 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.4 A | Air direction suction Power input 60 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P300-EC072-005 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.4 A | Air direction blowing Power input 60 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P300-EC072-100 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P300-EC092-001 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P300-EC092-002 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P300-EC092-003 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P300-EC092-004 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.1 A | Air direction suction Power input 160 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P300-EC092-005 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.1 A | Air direction blowing Power input 160 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P300-EC092-040 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P300-EC092-041 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P300-EC092-042 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P300-EC092-043 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P300-EC092-044 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.2 A | Air direction suction Power input 165 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P300-EC092-045 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.2 A | Air direction blowing Power input 165 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P300-EC092-100 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P315-EC092-001 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P315-EC092-004 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.1 A | Air direction suction Power input 165 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P315-EC092-005 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.1 A | Air direction blowing Power input 165 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P315-EC092-100 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P3450-EC102-045 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.8 A | Air direction blowing Power input 400 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P350-EC072-012 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.65 A | Air direction blowing Power input 90 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P350-EC072-013 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.65 A | Air direction blowing Power input 90 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P350-EC092-009 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.6 A | Air direction blowing Power input 90 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P350-EC092-040 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P350-EC092-041 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P350-EC092-042 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P350-EC092-043 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P350-EC092-044 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.1 A | Air direction suction Power input 165 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P350-EC092-045 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.1 A | Air direction blowing Power input 165 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P400-EC102-001 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P400-EC102-002 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P400-EC102-003 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P400-EC102-004 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.9 A | Air direction suction Power input 400 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P400-EC102-005 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.9 A | Air direction blowing Power input 400 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P400-EC102-100 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P450-EC092-001 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.72 A | Air direction suction Power input 100 W Working temperature -25 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P450-EC092-002 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P450-EC092-003 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.72 A | Air direction blowing Power input 100 W Working temperature -25 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P450-EC092-004 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P450-EC102-001 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P450-EC102-002 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P450-EC102-003 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P450-EC102-004 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.0 A | Air direction suction Power input 420 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P450-EC102-005 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.0 A | Air direction blowing Power input 420 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P450-EC102-016 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.15 A | Air direction blowing Power input 445 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P450-EC102-040 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P450-EC102-041 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P450-EC102-042 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P450-EC102-043 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P450-EC102-044 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.8 A | Air direction suction Power input 400 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P450-EC102-047 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 0.6 A | Air direction suction Power input 130 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P450-EC102-100 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P450-EC137-008 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.3 A | Air direction suction Power input 725 W Working temperature -30 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P500-EC102-001 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.4 A | Air direction blowing Power input 200 W Working temperature -25 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P500-EC102-100 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.4 A | Air direction suction Power input 200 W Working temperature -25 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P500-EC137-001 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P500-EC137-002 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P500-EC137-003 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P500-EC137-004 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.5 A | Air direction suction Power input 850 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P500-EC137-005 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.5 A | Air direction blowing Power input 850 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P500-EC137-017 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P500-EC137-050 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P500-EC137-051 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P500-EC137-052 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P500-EC137-053 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P500-EC137-054 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.3 A | Air direction suction Power input 1250 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P500-EC137-055 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.3 A | Air direction blowing Power input 1250 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P500-EC137-100 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P500-EC137-200 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P500-EC137-201 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P500-EC137-202 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P500-EC137-203 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P500-EC137-204 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.9 A | Air direction suction Power input 600 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P500-EC137-205 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.9 A | Air direction blowing Power input 600 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P500-EC137-250 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 3.5 A | Air direction suction Power input 770 W Working temperature -25 ~ +60 ᵒC Degree of protection IP55 | Model specifications Source documents |
| A3P500-EC137-910 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P500-EC137-911 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P500-EC137-912 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P500-EC137-913 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P500-EC137-914 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.8 A | Air direction suction Power input 1650 W Working temperature -20 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P500-EC137-915 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.8 A | Air direction blowing Power input 1650 W Working temperature -20 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P550-EC137-001 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P550-EC137-002 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P550-EC137-003 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P550-EC137-004 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.65 A | Air direction suction Power input 950 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P550-EC137-005 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.65 A | Air direction blowing Power input 950 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P550-EC137-050 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P550-EC137-051 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P550-EC137-052 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P550-EC137-053 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P550-EC137-054 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.9 A | Air direction suction Power input 1050 W Working temperature -25 ~ +60 ᵒC Degree of protection IP55 | Model specifications Source documents |
| A3P550-EC137-055 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.9 A | Air direction blowing Power input 1050 W Working temperature -25 ~ +60 ᵒC Degree of protection IP55 | Model specifications Source documents |
| A3P550-EC137-100 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P550-EC137-200 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P550-EC137-201 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P550-EC137-202 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P550-EC137-203 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P550-EC137-204 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.6 A | Air direction suction Power input 550 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P550-EC137-205 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.6 A | Air direction blowing Power input 550 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P550-EC137-910 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P550-EC137-911 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P550-EC137-912 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P550-EC137-913 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P550-EC137-914 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.74 A | Air direction suction Power input 1600 W Working temperature -25 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P550-EC137-915 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.74 A | Air direction blowing Power input 1600 W Working temperature -25 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P630-EC137-001 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-002 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P630-EC137-003 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P630-EC137-004 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.3 A | Air direction suction Power input 780 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P630-EC137-005 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.3 A | Air direction blowing Power input 780 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P630-EC137-007 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-050 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-051 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-052 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P630-EC137-053 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P630-EC137-054 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.8 A | Air direction suction Power input 1050 W Working temperature -20 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P630-EC137-055 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 1.8 A | Air direction blowing Power input 1050 W Working temperature -20 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P630-EC137-100 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-200 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-201 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-202 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P630-EC137-203 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P630-EC137-204 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.8 A | Air direction suction Power input 600 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P630-EC137-205 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.8 A | Air direction blowing Power input 600 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P630-EC137-207 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-260 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.75 A | Air direction suction Power input 600 W Working temperature -25 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P630-EC137-263 | Drive EC Supply 230 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.75 A | Air direction blowing Power input 600 W Working temperature -25 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P630-EC137-900 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-901 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-902 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P630-EC137-903 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P630-EC137-904 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.0 A | Air direction suction Power input 1200 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P630-EC137-905 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.0 A | Air direction blowing Power input 1200 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P630-EC137-910 | Drive EC | Air direction suction Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-911 | Drive EC | Air direction blowing Mounting arrangement With wall concave net cover grill | Model specifications Source documents |
| A3P630-EC137-912 | Drive EC | Air direction suction Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P630-EC137-913 | Drive EC | Air direction blowing Mounting arrangement With wind guide panel | Model specifications Source documents |
| A3P630-EC137-914 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.4 A | Air direction suction Power input 1400 W Working temperature -20 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P630-EC137-915 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.4 A | Air direction blowing Power input 1400 W Working temperature -20 ~ +60 ᵒC Degree of protection IP54 | Model specifications Source documents |
| A3P710-EC188-022 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.2 A | Air direction suction Power input 1280 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P710-EC188-023 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 2.2 A | Air direction blowing Power input 1280 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P800-EC188-022 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 3.0 A | Air direction suction Power input 1900 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P800-EC188-023 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 3.0 A | Air direction blowing Power input 1900 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P910-EC188-022 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 3.0 A | Air direction suction Power input 1800 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A3P910-EC188-023 | Drive EC Supply 3x400 VAC Frequency 50/60 Hz Control input 0-10 VDC / PWM Current draw 3.0 A | Air direction blowing Power input 1800 W Working temperature -25 ~ +60 ᵒC Degree of protection IP44 | Model specifications Source documents |
| A2E145S-5AN-AA10 | Drive AC Supply 220/230 V Frequency 50 / 60 Hz | Check the model-specific curve and drawing | Model specifications Source documents |
| A2D145S-5AN-AA10 | Drive AC Supply 380/400 V Frequency 50 / 60 Hz | Check the model-specific curve and drawing | Model specifications Source documents |
AFL axial fan family illustration. Select the model against the installed duty point.Heat-pump outdoor unitsPrepare an axial fan selection request with the coil, grille and enclosure layout.
AFL axial fan family illustration. Select the model against the installed duty point.Equipment cabinet coolingCompare fan candidates against the cabinet heat load, installed airflow resistance, available mounting space and electrical interface.
AFL axial fan family illustration. Select the model against the installed duty point.Condenser airflowCompare axial options against the actual coil and grille.
AFL product family illustration · axial fan. Individual mounting and accessories vary by suffix.Which details belong in a heat-pump fan inquiry?Record the operating points, outdoor enclosure dimensions and power supply before comparing fan proposals.
B3P220-EC072-100 product photo · AFL catalogue, page 87.Which details belong in an EC control-interface request?A reference to variable speed leaves the electrical interface and feedback requirements open. Describe the controller output and the response expected by the equipment.
AFL product family illustration · axial fan. Individual mounting and accessories vary by suffix.What should accompany an outdoor heat-pump coil drawing?Add the grille position, intended flow direction, available space and relevant operating points. The mounting dimensions alone do not describe coil resistance.
AFL product family illustration · axial fan. Individual mounting and accessories vary by suffix.How do I specify a DC fan for an equipment cabinet?Describe the DC bus range at the fan terminals, available current, enclosure air path and required cooling conditions.
AFL product family illustration · axial fan. Individual mounting and accessories vary by suffix.What should I ask when two suppliers quote different selection points?First align the units and confirm whether both proposals quote static or total pressure. Check that each refers to the same assembly and control setting.