AFL Motors

Air-handling units

Review a centrifugal fan for an air-handling unit against the full equipment duty point and the space available for service.

Framed B400 fan for AHU review · AFL equipment presentation, slide 25.
Framed B400 fan for AHU review · AFL equipment presentation, slide 25.

Define the operating point

Give the intended airflow and the corresponding static pressure with units. Include the installation drawing and access envelope. Mark the agreed selection point on the proposed fan curve before releasing a sample request.

Paired operating points

Slides 23–27 list specific airflow and static pressure pairs. A bare fan and a framed variant may require different mounting space. Ask for the curve and drawing for the quoted suffix.

Reference details for the linked options
OptionReference fieldValue
B3P series EC centrifugal fansFamilyB3P series
B3P series EC centrifugal fansDriveEC
B3P series EC centrifugal fansSelection documentRequest the curve and installation drawing for the proposed model
Application duty points from the AFL presentation
Full modelAirflow (m³/h)Static pressure (Pa)Slide
B3P456-EC137-950500090024
B3P456-EC137-9504000100024
B3P400-EC188-0318000100025
B3P400-EC188-0316000130025
B3P400-EC188-0328000100025
B3P400-EC188-0326000130025
B3P450-EC188-9511500090026
B3P450-EC188-95112000130026
B3P450-EC188-95110000160026
B3P355-EC188-0243500180027
B3P355-EC188-0243000210027

Sources

Related documents and engineering decisions

FFU, data centre and AHU engineering presentation · p. 23 Browse all manufacturer documentsFilter candidates by documented specifications

Engineering guides

AFL product family illustration · centrifugal fan. Individual mounting and accessories vary by suffix.AFL product family illustration · centrifugal fan. Individual mounting and accessories vary by suffix.What should an AHU buyer send for fan selection?Pair the required airflow with static pressure and the installation envelope so suppliers can compare options at the same duty point.B3P280-EC092-004 product photo · AFL catalogue, page 103.B3P280-EC092-004 product photo · AFL catalogue, page 103.How do I compare two curves at the same duty point?Record airflow and static pressure together. A maximum free-air flow is measured at a different point from operation against an installed filter or coil.AFL product family illustration · centrifugal fan. Individual mounting and accessories vary by suffix.AFL product family illustration · centrifugal fan. Individual mounting and accessories vary by suffix.How should I describe clean and loaded filters in an AHU RFQ?A clean filter and a loaded filter can put the same fan at different operating points. State which condition each system pressure represents.Framed B400 fan for AHU review · AFL equipment presentation, slide 25.Framed B400 fan for AHU review · AFL equipment presentation, slide 25.How should I quote an AHU fan at two operating points?State each airflow together with its static pressure and keep bare and framed variants separate.

Relevant product families

AFL centrifugal fan family illustration. Mounting configuration and accessories vary by complete model suffix.AFL product family illustration · centrifugal fan. Individual mounting and accessories vary by suffix.B3P series EC centrifugal fansB3P EC backward-curved fans for air-handling equipment. Compare performance curves and mounting drawings to shortlist a model for your duty point.B456 installation drawing · AFL equipment presentation, slide 24.B456 installation drawing · AFL equipment presentation, slide 24.B3P456-EC137-950B3P456-EC137-950: review air-handling unit fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.Framed B400 configuration · AFL equipment presentation, slide 25.Framed B400 configuration · AFL equipment presentation, slide 25.B3P400-EC188-031B3P400-EC188-031: review air-handling unit fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.Framed B400 configuration · AFL equipment presentation, slide 25.Framed B400 configuration · AFL equipment presentation, slide 25.B3P400-EC188-032B3P400-EC188-032: review air-handling unit fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.B450 impeller illustration · AFL equipment presentation, slide 26.B450 impeller illustration · AFL equipment presentation, slide 26.B3P450-EC188-951B3P450-EC188-951: review air-handling unit fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.B3P355-EC188-024 product photo · AFL catalogue, page 141.B3P355-EC188-024 product photo · AFL catalogue, page 141.B3P355-EC188-024B3P355-EC188-024: review air-handling unit fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.

Related equipment and applications

2 × 4 fan filter unit · AFL equipment presentation, slide 4.2 × 4 fan filter unit · AFL equipment presentation, slide 4.Cleanroom fan filter units (FFUs)Choose the FFU size, controller and fan together. Compare airflow at filter pressure drop and confirm the shaft and feedback configuration.