Data centre cooling: in-row units and fan walls

Match the airflow and static pressure of the cooling unit with the available depth, power supply and fan arrangement.

In-row cooling equipment · AFL equipment presentation, slide 16.
In-row cooling equipment · AFL equipment presentation, slide 16.

In-row versus fan-wall selection

The in-row examples range from compact 48 VDC units to larger centrifugal fans. The fan-wall example lists 12,460 m³/h at 1,080 Pa. Confirm whether the submitted requirement applies to one fan or the full wall.

Application duty points from the AFL presentation
Full modelAirflow (m³/h)Static pressure (Pa)Slide
B3P456-EC137-001485035016
B3P640-EC188-90112460108017
B3P225-EC072-00884042018
A3P500-EC102-008400019019
A3P180-DC092-002116075020
A3P200-DC072-02711006521
B3P225-DC072-90369054022

Related documents and engineering decisions

FFU, data centre and AHU engineering presentation · p. 15 Browse all manufacturer documentsFilter candidates by documented specifications

Engineering guides

AFL product family illustration · axial fan. Individual mounting and accessories vary by suffix.AFL product family illustration · axial fan. Individual mounting and accessories vary by suffix.What should I ask when two suppliers quote different selection points?First align the units and confirm whether both proposals quote static or total pressure. Check that each refers to the same assembly and control setting.In-row cooling equipment · AFL equipment presentation, slide 16.In-row cooling equipment · AFL equipment presentation, slide 16.Which duty point applies to a fan wall or an in-row cooler?Compare paired pressure and flow values for the equipment arrangement you are buying.

Relevant product families

B3P456-EC137-001 product photo · AFL catalogue, page 166.B3P456-EC137-001 product photo · AFL catalogue, page 166.B3P456-EC137-001B3P456-EC137-001: review equipment cooling fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.Fan-wall impeller · AFL equipment presentation, slide 17.Fan-wall impeller · AFL equipment presentation, slide 17.B3P640-EC188-901B3P640-EC188-901: review equipment cooling fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.B3P225-EC072-008 product photo · AFL catalogue, page 92.B3P225-EC072-008 product photo · AFL catalogue, page 92.B3P225-EC072-008B3P225-EC072-008: review equipment cooling fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.EC axial fan · AFL equipment presentation, slide 19.EC axial fan · AFL equipment presentation, slide 19.A3P500-EC102-008A3P500-EC102-008: review equipment cooling fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.DC fan · AFL equipment presentation, slide 20.DC fan · AFL equipment presentation, slide 20.A3P180-DC092-002A3P180-DC092-002: review equipment cooling fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.DC panel fan · AFL equipment presentation, slide 21.DC panel fan · AFL equipment presentation, slide 21.A3P200-DC072-027A3P200-DC072-027: review equipment cooling fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.Enclosed DC fan · AFL equipment presentation, slide 22.Enclosed DC fan · AFL equipment presentation, slide 22.B3P225-DC072-903B3P225-DC072-903: review equipment cooling fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.

Related equipment and applications

AFL axial fan family illustration. Select the model against the installed duty point.AFL axial fan family illustration. Select the model against the installed duty point.Condenser airflowCompare axial options against the actual coil and grille.