Double-inlet centrifugal blowerF3P146-EC092-055
F3P146-EC092-055 is an AFL double-inlet centrifugal blower in the published model records. Review its documented specifications, installation requirements and source information against your equipment duty.

Review the documented model data
Supply: 230 VAC. Frequency: 50/60 Hz. Power input: 115 W. Speed: 1600 rpm. Control input: 0-10 VDC / PWM. The AFL catalogue lists 230 VAC, 50/60 Hz, 115 W for this double-inlet centrifugal blower. Check the 0-10 VDC / PWM control interface against your controller. The catalogue enclosure rating is IP44.
Check the installation and operating point
Check clearance at both intake openings, the outlet orientation and the fixing positions against the model drawing. Include the cabinet, filter and duct losses in the required duty point.
Match the electrical interface
Confirm the supply and the exact speed-control and feedback interface required by the equipment controller. An EC designation alone does not establish the supported control signal.
Use the technical documents
Check the attached model documents and their page references before sample evaluation. Confirm the complete suffix and document revision. Performance at your required duty point must be checked on the corresponding curve.
Discuss this model
Include F3P146-EC092-055, required airflow and static pressure, power supply and available installation space in your inquiry. Attach the equipment layout and identify any required control or feedback signals.
EC fans and blowers · Double-inlet blowers
Specifications
- Model
- F3P146-EC092-055
- Drive
- EC
- Supply
- 230 VAC
- Frequency
- 50/60 Hz
- Current draw
- 0.8 A
- Power input
- 115 W
- Speed
- 1600 rpm
- Control input
- 0-10 VDC / PWM
- Sound pressure level
- 61 dB
- Degree of protection
- IP44
- Working temperature
- -25 ~ +60 °C
- Insulation class
- B
- Impeller material
- galvanised sheet steel
Manufacturer catalogue pages
Check the drawing and rated conditions for the complete model.
Catalogue page 217| Catalogue field | Value on this page |
|---|---|
| Supply | 230 VAC |
| Frequency | 50/60 Hz |
| Current draw | 0.8 A |
| Power input | 115 W |
| Speed | 1600 rpm |
| Control input | 0-10 VDC / PWM |
| Sound pressure level | 61 dB |
| Degree of protection | IP44 |
| Working temperature | -25 ~ +60 °C |
| Insulation class | B |
| Impeller material | galvanised sheet steel |
Equipment fit and selection
Check both inlet clearances and the discharge orientation in the cabinet drawing. Provide the working point with the filter and duct losses included.
Equipment selection guide What to check before ordering Factory and qualification documentsRelated models to review
Compare the complete suffix, mounting and operating conditions before specifying a replacement.
F3P146-EC092-035 product photo · AFL catalogue, page 218.F3P146-EC092-035F3P146-EC092-035: review double-inlet centrifugal blower specifications, mounting requirements and technical sources before selecting a fan for your equipment.
F3P146-EC092-057 product photo · AFL catalogue, page 219.F3P146-EC092-057F3P146-EC092-057: review double-inlet centrifugal blower specifications, mounting requirements and technical sources before selecting a fan for your equipment.
F3P146-EC092-608 product photo · AFL catalogue, page 220.F3P146-EC092-608F3P146-EC092-608: review double-inlet centrifugal blower specifications, mounting requirements and technical sources before selecting a fan for your equipment.