Review the documented model data

Supply: 220/230 V. Frequency: 50 Hz. Power input: 100 W. Speed: 1320 rpm. The AC forward catalogue lists 100 W input and 1320 rpm at 220/230 V, 50 Hz. Compare the installed duty point with curve 2 and check the shared F146-190S mounting drawing.

Check the installation and operating point

Check clearance at both intake openings, the outlet orientation and the fixing positions against the model drawing. Include the cabinet, filter and duct losses in the required duty point.

Match the electrical interface

Confirm the supply and frequency required by the equipment. Keep separate frequency ratings and speed configurations distinct when comparing candidates.

Use the technical documents

Check the attached model documents and their page references before sample evaluation. Confirm the complete suffix and document revision. Performance at your required duty point must be checked on the corresponding curve.

Discuss this model

Include F4E146-190S-AE00, required airflow and static pressure, power supply and available installation space in your inquiry. Attach the equipment layout and identify any required control or feedback signals.

AC fans and blowers · Double-inlet blowers

Specifications

Model
F4E146-190S-AE00
Drive
AC
Supply
220/230 V
Frequency
50 Hz
Power input
100 W
Speed
1320 rpm
Current draw
0.54 A
Catalogue airflow
750 m³/h
Noise
52 dB(A)
Working temperature
-30 to +60 °C
View original drawing or performance sheet · page 26AC dual-inlet forward-curved blower F4E146-190S-AE00 manufacturer sheet, page 26

Open original PDF at this page

Source and operating conditions

Transcribed from the supplied AC Forward Centrifugal catalogue, PDF image page 26, printed page 44. The airflow is a catalogue table value. Check the corresponding curve at your installed static pressure. The F146-190S drawing includes mounting positions and rotation direction. Verify the current revision before ordering.

Compare this modelCheck evidenceAsk engineering about this model

Equipment fit and selection

Provide inlet clearance on both sides, outlet orientation, airflow and static pressure, supply and frequency before selecting a dual-inlet blower.

Double-inlet installation conditions AC forward catalogue

Related models to review

Compare the complete suffix, mounting and operating conditions before specifying a replacement.

F2E146-190S-AG00 manufacturer product image. Verify the complete suffix against the source drawing.AC double-inlet family illustration. Verify the specific construction against the linked manufacturer sheet.AC dual-inlet forward-curved blower F2E146-190S-AG00The AC forward catalogue lists 250 W input and 1500 rpm at 220/230 V, 50 Hz. Compare the installed duty point with curve 1 and check the shared F146-190S mounting drawing.

Request specifications

Your inquiry will be saved for the AFL team. For direct contact, use the sales details on the Contact page.