Single-inlet centrifugal blower F3P160-EC092-637
F3P160-EC092-637 is an AFL single-inlet centrifugal blower in the published model records. Review its documented specifications, installation requirements and source information against your equipment duty.

Review the documented model data
Supply: 230 VAC. Frequency: 50/60 Hz. Power input: 110 W. Speed: 1900 rpm. Control input: 0-10 VDC / PWM. The AFL catalogue lists 230 VAC, 50/60 Hz, 110 W for this single-inlet centrifugal blower. Check the 0-10 VDC / PWM control interface against your controller. The catalogue enclosure rating is IP44.
Check the installation and operating point
Check the available inlet clearance, scroll outlet orientation and mounting positions. Compare the installed air path and available cabinet space with the model drawing.
Match the electrical interface
Confirm the supply and the exact speed-control and feedback interface required by the equipment controller. An EC designation alone does not establish the supported control signal.
Use the technical documents
Check the attached model documents and their page references before sample evaluation. Confirm the complete suffix and document revision. Performance at your required duty point must be checked on the corresponding curve.
Discuss this model
Include F3P160-EC092-637, required airflow and static pressure, power supply and available installation space in your inquiry. Attach the equipment layout and identify any required control or feedback signals.
EC fans and blowers · Single-inlet blowers
Specifications
- Model
- F3P160-EC092-637
- Drive
- EC
- Supply
- 230 VAC
- Frequency
- 50/60 Hz
- Current draw
- 0.75 A
- Power input
- 110 W
- Speed
- 1900 rpm
- Control input
- 0-10 VDC / PWM
- Sound pressure level
- 67 dB
- Degree of protection
- IP44
- Working temperature
- -25 ~ +60 °C
- Insulation class
- B
- Impeller material
- PA66
Manufacturer catalogue pages
Check the drawing and rated conditions for the complete model.
Catalogue page 200| Catalogue field | Value on this page |
|---|---|
| Supply | 230 VAC |
| Frequency | 50/60 Hz |
| Current draw | 0.75 A |
| Power input | 110 W |
| Speed | 1900 rpm |
| Control input | 0-10 VDC / PWM |
| Sound pressure level | 67 dB |
| Degree of protection | IP44 |
| Working temperature | -25 ~ +60 °C |
| Insulation class | B |
| Impeller material | PA66 |
Equipment fit and selection
For air-handling equipment, specify airflow together with static pressure, mounting space and speed control. Confirm the selected suffix against the equipment drawing.
Equipment selection guide What to check before ordering Factory and qualification documentsRelated models to review
Compare the complete suffix, mounting and operating conditions before specifying a replacement.
F3P160-EC072-100 product photo · AFL catalogue, page 197.F3P160-EC072-100F3P160-EC072-100: review single-inlet centrifugal blower specifications, mounting requirements and technical sources before selecting a fan for your equipment.
F3P160-EC092-100 product photo · AFL catalogue, page 202.F3P160-EC092-100F3P160-EC092-100: review single-inlet centrifugal blower specifications, mounting requirements and technical sources before selecting a fan for your equipment.
F3P160-EC092-665 product photo · AFL catalogue, page 201.F3P160-EC092-665F3P160-EC092-665: review single-inlet centrifugal blower specifications, mounting requirements and technical sources before selecting a fan for your equipment.