Equipment cooling fan A3P180-DC092-002
A3P180-DC092-002 is an AFL equipment cooling fan in the published model records. Review its documented specifications, installation requirements and source information against your equipment duty.

Review the documented model data
Supply: 48 VDC. Data centre cooling: in-row units and fan walls. Presentation slide 20 lists 1,160 m³/h at 750 Pa. Confirm the test arrangement and proposed revision for your equipment.
Check the installation and operating point
Check air direction, guard and inlet clearance, mounting positions and the coil or grille layout. Evaluate the curve using the resistance of the complete installed air path.
Match the electrical interface
State the DC supply range at the fan terminals and confirm the control and feedback requirements for this complete model.
Use the technical documents
Check the attached model documents and their page references before sample evaluation. Confirm the complete suffix and document revision. Performance at your required duty point must be checked on the corresponding curve.
Discuss this model
Include A3P180-DC092-002, required airflow and static pressure, power supply and available installation space in your inquiry. Attach the equipment layout and identify any required control or feedback signals.
DC fans and blowers · Equipment cooling fans
Specifications
- Model
- A3P180-DC092-002
- Supply
- 48 VDC
- Drive
- DC
Selection from the source sheet
Data centre cooling: in-row units and fan walls. Presentation slide 20 lists 1,160 m³/h at 750 Pa. Confirm the test arrangement and proposed revision for your equipment.
| Airflow (m³/h) | Static pressure (Pa) |
|---|---|
| 1160 | 750 |
Related documents and engineering decisions
FFU, data centre and AHU engineering presentation · p. 20Equipment fit and selection
For equipment cooling, verify the load, available depth and airflow path. Confirm the supply and the paired pressure and flow before selecting a variant.
Equipment selection guide What to check before ordering Factory and qualification documentsRelated models to review
Compare the complete suffix, mounting and operating conditions before specifying a replacement.
Related resources and guides
FFU, data centre and AHU engineering presentation · source previewTechnical resourcesFFU, data centre and AHU engineering presentationApplication-specific models, paired duty points, controller configurations and equipment-level test examples.
In-row cooling equipment · AFL equipment presentation, slide 16.ApplicationsData centre cooling: in-row units and fan wallsMatch the airflow and static pressure of the cooling unit with the available depth, power supply and fan arrangement.
DC panel fan · AFL equipment presentation, slide 21.A3P200-DC072-027