AFL Motors

Equipment cooling fan B3P225-EC072-008

B3P225-EC072-008 is an AFL equipment cooling fan in the published model records. Review its documented specifications, installation requirements and source information against your equipment duty.

B3P225-EC072-008 product photo · AFL catalogue, page 92.
B3P225-EC072-008 product photo · AFL catalogue, page 92.

Review the documented model data

Supply: 230 VAC. Frequency: 50/60 Hz. Power input: 170 W. Speed: 3000 rpm. Control input: 0-10 VDC / PWM. The AFL catalogue lists 230 VAC, 50/60 Hz, 170 W for this equipment cooling fan. Check the 0-10 VDC / PWM control interface against your controller. The catalogue enclosure rating is IP44.

Check the installation and operating point

Provide the enclosure layout, available depth and intake and exhaust paths. Compare the fan mounting and electrical interface with the equipment drawing.

Match the electrical interface

Confirm the supply and the exact speed-control and feedback interface required by the equipment controller. An EC designation alone does not establish the supported control signal.

Use the technical documents

Check the attached model documents and their page references before sample evaluation. Confirm the complete suffix and document revision. Performance at your required duty point must be checked on the corresponding curve.

Discuss this model

Include B3P225-EC072-008, required airflow and static pressure, power supply and available installation space in your inquiry. Attach the equipment layout and identify any required control or feedback signals.

EC fans and blowers · Equipment cooling fans

All B3P225-EC072 variants

Specifications

Model
B3P225-EC072-008
Drive
EC
Supply
230 VAC
Frequency
50/60 Hz
Current draw
1.16 A
Power input
170 W
Speed
3000 rpm
Control input
0-10 VDC / PWM
Sound pressure level
79 dB
Degree of protection
IP44
Working temperature
-25 ~ +60 °C
Insulation class
B
Impeller material
PA66

Manufacturer catalogue pages

Check the drawing and rated conditions for the complete model.

Catalogue page 92
View original drawing or performance sheet · page 92B3P225-EC072-008 manufacturer sheet, page 92

Open original PDF at this page

Selection from the source sheet

Data centre cooling: in-row units and fan walls. Presentation slide 18 lists 840 m³/h at 420 Pa. Confirm the test arrangement and proposed revision for your equipment.

Operating points in the equipment presentation
Airflow (m³/h)Static pressure (Pa)
840420
AFL product catalogue · page 92
Catalogue fieldValue on this page
Supply230 VAC
Frequency50/60 Hz
Current draw1.16 A
Power input170 W
Speed3000 rpm
Control input0-10 VDC / PWM
Sound pressure level79 dB
Degree of protectionIP44
Working temperature-25 ~ +60 °C
Insulation classB
Impeller materialPA66

Related documents and engineering decisions

FFU, data centre and AHU engineering presentation · p. 18 EC backward-curved centrifugal fan catalogue · p. 17
Compare this modelCheck evidenceAsk engineering about this model

Equipment fit and selection

For equipment cooling, verify the load, available depth and airflow path. Confirm the supply and the paired pressure and flow before selecting a variant.

Equipment selection guide What to check before ordering Factory and qualification documents

Related models to review

Compare the complete suffix, mounting and operating conditions before specifying a replacement.

B3P456-EC137-001 product photo · AFL catalogue, page 166.B3P456-EC137-001 product photo · AFL catalogue, page 166.B3P456-EC137-001B3P456-EC137-001: review equipment cooling fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.Fan-wall impeller · AFL equipment presentation, slide 17.Fan-wall impeller · AFL equipment presentation, slide 17.B3P640-EC188-901B3P640-EC188-901: review equipment cooling fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.

Related resources and guides

EC backward-curved centrifugal fan catalogue · source previewEC backward-curved centrifugal fan catalogue · source previewTechnical resourcesEC backward-curved centrifugal fan catalogueUse the full EC fan designation to locate the curve, control wiring and installation drawing.FFU, data centre and AHU engineering presentation · source previewFFU, data centre and AHU engineering presentation · source previewTechnical resourcesFFU, data centre and AHU engineering presentationApplication-specific models, paired duty points, controller configurations and equipment-level test examples.In-row cooling equipment · AFL equipment presentation, slide 16.In-row cooling equipment · AFL equipment presentation, slide 16.ApplicationsData centre cooling: in-row units and fan wallsMatch the airflow and static pressure of the cooling unit with the available depth, power supply and fan arrangement.

Request specifications

Your inquiry will be saved for the AFL team. For direct contact, use the sales details on the Contact page.