Equipment cooling fan B3P456-EC137-001
B3P456-EC137-001 is an AFL equipment cooling fan in the published model records. Review its documented specifications, installation requirements and source information against your equipment duty.

Review the documented model data
Supply: 3x400 VAC. Frequency: 50/60 Hz. Power input: 675 W. Speed: 1800 rpm. Control input: 0-10 VDC / PWM. The AFL catalogue lists 3x400 VAC, 50/60 Hz, 675 W for this equipment cooling fan. Check the 0-10 VDC / PWM control interface against your controller. The catalogue enclosure rating is IP55.
Check the installation and operating point
Provide the enclosure layout, available depth and intake and exhaust paths. Compare the fan mounting and electrical interface with the equipment drawing.
Match the electrical interface
Confirm the supply and the exact speed-control and feedback interface required by the equipment controller. An EC designation alone does not establish the supported control signal.
Use the technical documents
Check the attached model documents and their page references before sample evaluation. Confirm the complete suffix and document revision. Performance at your required duty point must be checked on the corresponding curve.
Discuss this model
Include B3P456-EC137-001, required airflow and static pressure, power supply and available installation space in your inquiry. Attach the equipment layout and identify any required control or feedback signals.
EC fans and blowers · Equipment cooling fans
Specifications
- Model
- B3P456-EC137-001
- Drive
- EC
- Supply
- 3x400 VAC
- Frequency
- 50/60 Hz
- Current draw
- 1.2 A
- Power input
- 675 W
- Speed
- 1800 rpm
- Control input
- 0-10 VDC / PWM
- Sound pressure level
- 79 dB
- Degree of protection
- IP55
- Working temperature
- -25 ~ +60 °C
- Insulation class
- F
- Impeller material
- sheet aluminium
Manufacturer catalogue pages
Check the drawing and rated conditions for the complete model.
Catalogue page 166Selection from the source sheet
Data centre cooling: in-row units and fan walls. Presentation slide 16 lists 4,850 m³/h at 350 Pa. Confirm the test arrangement and proposed revision for your equipment.
| Airflow (m³/h) | Static pressure (Pa) |
|---|---|
| 4850 | 350 |
| Catalogue field | Value on this page |
|---|---|
| Supply | 3x400 VAC |
| Frequency | 50/60 Hz |
| Current draw | 1.2 A |
| Power input | 675 W |
| Speed | 1800 rpm |
| Control input | 0-10 VDC / PWM |
| Sound pressure level | 79 dB |
| Degree of protection | IP55 |
| Working temperature | -25 ~ +60 °C |
| Insulation class | F |
| Impeller material | sheet aluminium |
Related documents and engineering decisions
FFU, data centre and AHU engineering presentation · p. 16Equipment fit and selection
For equipment cooling, verify the load, available depth and airflow path. Confirm the supply and the paired pressure and flow before selecting a variant.
Equipment selection guide What to check before ordering Factory and qualification documentsRelated models to review
Compare the complete suffix, mounting and operating conditions before specifying a replacement.
B3P225-EC072-008 product photo · AFL catalogue, page 92.B3P225-EC072-008B3P225-EC072-008: review equipment cooling fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.
Fan-wall impeller · AFL equipment presentation, slide 17.B3P640-EC188-901B3P640-EC188-901: review equipment cooling fan specifications, mounting requirements and technical sources before selecting a fan for your equipment.Related resources and guides
FFU, data centre and AHU engineering presentation · source previewTechnical resourcesFFU, data centre and AHU engineering presentationApplication-specific models, paired duty points, controller configurations and equipment-level test examples.
In-row cooling equipment · AFL equipment presentation, slide 16.ApplicationsData centre cooling: in-row units and fan wallsMatch the airflow and static pressure of the cooling unit with the available depth, power supply and fan arrangement.
In-row cooling equipment · AFL equipment presentation, slide 16.Selection guideWhich duty point applies to a fan wall or an in-row cooler?Compare paired pressure and flow values for the equipment arrangement you are buying.